For research use only · Availability varies by countryinfo@redprobes.com
Heparin Red® mix-and-read assays

Direct heparin detection within minutes.

Heparin Red® fluorescence assays measure the “chemical” heparin concentration in µg/mL — independent of the clotting cascade. Mix, read, done.

Heidelberg spin-offChemistry, Heidelberg University
Peer-reviewedChem Commun 2010 · Anal Bioanal Chem 2016
96-well formatStandard plate reader
Multichannel pipette tips drawing red liquid from a reservoir next to a 96-well microplate
20 µLplasma per test
Calibrationµg/mL
≈ 1 µg/mL detection limit

Detects

  • unfractionated heparin
  • complex matrices (matrix)
  • UFH
  • enoxaparin
  • chemically modified heparins
  • serum (matrix)
  • heparan sulfate
  • LMWH
  • plasma (matrix)
  • fucoidan
  • non-anticoagulant heparins
  • urine (matrix)
  • octasaccharide

Red: heparins and related compounds · grey: sample matrices, also aqueous samples

Applications

From the research bench to drug development

Where a direct, chemical measurement of heparin matters more than its effect on clotting.

Pharmacokinetic studies

Follow non-anticoagulant heparins — a promising class of drug candidates — in human plasma, where clotting-based assays cannot see them.

Heparins in aqueous samples

Fast, very convenient quantification of heparin content in aqueous solutions, e.g. for checking preparations in the lab, from only 5 µL.

Heparin-related research

Chemically modified heparins, heparan sulfate, fucoidan and other sulfated oligosaccharides — measured directly, independent of anticoagulant activity.

RecommendedCompare both →

Technology

How Heparin Red® works

  1. Mix

    Add sample and Heparin Red® reagent to a 96-well microplate.

  2. Read

    Measure fluorescence on a standard microplate reader — within minutes.

  3. Quantify

    Get the heparin concentration in µg/mL from the calibration.

The key component of our assays is Heparin Red®, a synthetic molecular probe that changes fluorescence intensity when associating with a polyanionic heparin target [1, 2]. Heparin Red was designed as a fluorescent probe that emits orange-red light, in order to reduce interference by coloured components and autofluorescence in biological samples.

Our technology enables the direct detection of heparins and related compounds by a simple mix-and-read microplate assay, independent of any anticoagulant activity.

References
  1. Szelke H, Schuebel S, Harenberg J, Krämer R. A fluorescent probe for the quantification of heparin in clinical samples with minimal matrix interference. Chem Commun 2010; 46: 1667–1669.
  2. Warttinger U, Giese C, Harenberg J, Holmer E, Krämer R. A fluorescent probe assay (Heparin Red) for direct detection of heparins in human plasma. Anal Bioanal Chem 2016; 408: 8241–8251.
  3. Cassinelli G, Naggi A. Old and new applications of non-anticoagulant heparin. Int J Cardiol 2016; 212 Suppl 1: S14–S21.
  4. Galli M, Magen H, Einsele H, et al. Roneparstat (SST0001), an innovative heparanase (HPSE) inhibitor for multiple myeloma (MM) therapy: first in man study. Blood 2015; 126: 3246.
A vial of Heparin Red reagent glowing red under UV light, with a fluorescent Redprobes label
Calibration of Heparin Red® Ultra: normalised fluorescence versus heparin concentration Seven measurements from 0 to 6 µg/mL heparin. Normalised fluorescence falls linearly from 1 at 0 µg/mL to about 0.33 at 6 µg/mL. 00.20.40.60.81 0246 Heparin (µg/mL) Normalised fluorescence
Left: Heparin Red® reagent fluorescing orange-red under excitation (photo: Redprobes). Right: fluorescence decreases as the heparin concentration rises — redrawn from Redprobes’ calibration plot for Heparin Red® Ultra.

Products

Choose your assay

Both measure “chemical” heparin concentrations in µg/mL, not the effect of heparin on the clotting cascade.

Request a quote
Research use onlyGloved hands holding a 96-well microplate with red-filled wells
For human plasma

Heparin Red® Kit

Optimised for the direct detection of heparins in human plasma [2]. The Kit has emerged as a tool for pharmacokinetic studies of non-anticoagulant heparins, a promising class of drug candidates [3, 4].

  • Convenient mix-and-read fluorescence assay for microplates
  • Direct detection of heparins in only 20 µL plasma
  • Detection limit about 1 µg/mL (UFH in spiked pool plasma)
  • Detects non-anticoagulant heparins and related compounds
  • Robust, protein-free reagents
Research use onlyTwelve pipette tips dispensing pink liquid into a reservoir on a pipetting station
For aqueous samples

Heparin Red® Ultra

Optimised for the fast and very convenient detection of heparins with low interference in aqueous samples.

  • Convenient mix-and-read fluorescence assay for microplates
  • Direct detection of heparins in only 5 µL sample
  • Detection limit about 1 µg/mL (UFH in water)
  • Robust, protein-free reagents
Side-by-side
SpecificationHeparin Red® KitHeparin Red® Ultra
Sample typeHuman plasmaAqueous samples
Sample volume20 µL5 µL
Detection limit≈ 1 µg/mL (UFH, spiked pool plasma)≈ 1 µg/mL (UFH in water)
Assay formatMix-and-read, 96-well microplateMix-and-read, 96-well microplate
Pack size≈ 100 or 500 determinations1 vial, ≈ 100 determinations
Non-anticoagulant heparins✓ DetectedAsk us
ReagentsRobust, protein-freeRobust, protein-free
Intended useResearch use onlyResearch use only

Get a quote

Request a quote in one minute

We reply by email with price and availability for your country.

Your request

Submitting opens your email program with a pre-filled message to info@redprobes.com — nothing is stored on this website.

Product
See our privacy policy. Products are supplied exclusively for research purposes and laboratory use.

About us

Fast, user-friendly tests for heparins

Redprobes specialises in the development of fast and user-friendly tests for the direct detection of heparins and related compounds in various matrices. We aim to provide convenient and cost-effective analytical solutions to researchers in the life sciences and pharmaceutical space.

The company’s proprietary, patent-protected technology enables the direct measurement of heparin concentrations in µg/mL, independent of the effect on the clotting cascade.

Professor Roland Krämer is a founder of Redprobes. He holds a chair in Chemistry at Heidelberg University and has published extensively on the development of molecular sensors and assays for bioanalytical and diagnostic applications.

“Sometimes the simplest solution is the best.”
Scientist in a lab coat pipetting samples at the bench
Prof. Dr. Roland KrämerFounder · Chair of Chemistry, Heidelberg University
Dr. Yanet Basulto SolisManaging director
Eppelheim · Heidelberg region
Handelsstraße 24, 69214 Eppelheim, Germany

Publications

Publications related or referring to Redprobes technology

Redprobes is not in any way responsible for the contents and accuracy of the publications listed below.

2016
A fluorescent probe assay (Heparin Red) for direct detection of heparins in human plasma
Warttinger U, Giese C, Harenberg J, Holmer E, Krämer R. Anal Bioanal Chem 408, 8241–8251
Heparin Red® KitPlasma
View article ↗
2010
A fluorescent probe for the quantification of heparin in clinical samples with minimal matrix interference
Szelke H, Schuebel S, Harenberg J, Krämer R. Chem Commun 46, 1667–1669
MethodProbe design
View article ↗

Contact

Talk to us

Address

Redprobes UG (haftungsbeschränkt)
Handelsstraße 24
69214 Eppelheim, Germany

Quotes

Price and availability for your country.

Get a quote
EmailGet a quote